Features
- Filters available in single stage and double stage.
- All filters provide high attenuation performance.
- All filters compliance to EN60939-3:2015 & EN60939-2:2005 standards.
- Filter available in panel mounting provision.
- CRCA metal can with nickel plating provides good aesthetic and corrosion protection.
- High reliable
- Input connection through IEC 60320 C20 plug
- Have choice to select output connection type.
- Filters available in medical version without capacitor to earth.
- With surge suppressor filters also available.
- Applications - Consumer product, Medical equipment, Industrial application, Electrical automation equipment, Solar inverter
Specification
Technical specifications
Sr. No. | Parameters | Specification |
---|---|---|
1 | Operating voltage | 120/250 VAC |
2 | Current rating | 1A-20A |
3 | Frequency | 50/60Hz |
4 | Voltage drop | 1 Volt max. |
5 | High potential test voltage | P -> E 1500VAC P -> N 1414VDC (applicable for excluding surge suppressor filter) |
6 | Insulation resistance | ≥ 300 MΩ @ 500VDC (PN→E) |
7 | Operating temperature | 40°c /-25°c +85°c |
Safety approvals/Compliance Marking
Sr. No. | Parameters | Specification |
---|---|---|
1 | cCSAus | Yes |
2 | CE, RoHS | Yes |